{"cve":{"cve_id":"CVE-2020-12028","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.51023,"epss_percentile":0.98786,"epss_as_of":"2026-06-23","description":"In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.","published_at":"2020-07-20T15:17:11.738000Z","last_modified_at":null,"cvss_v3_score":7.3,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-264"],"nvd_references":["https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05","https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944","http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:13:21.313572Z"},"effective_severity":"HIGH","badges":["epss"],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"R","value_label":"Required"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"N","value_label":"None"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"rockwell-automation","vendor_name":"Rockwell Automation","product_slug":"factorytalk-view-se","product_name":"FactoryTalk® View SE","version_start":"all versions","version_start_inclusive":true,"version_end":"all versions","version_end_inclusive":true,"cpe23_uri":"cve5:rockwell-automation:factorytalk-view-se:all versions:all versions"}],"exploit_refs":[],"news":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05","source_type":"VENDOR_ADVISORY","tags":["advisory"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944","source_type":"MISC","tags":[]},{"url":"http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html","source_type":"EXPLOIT","tags":["exploit"]}],"timeline":[{"type":"published","at":"2020-07-20T15:17:11.738000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:02:06.718090Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:02:06.718090Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:02:06.718090Z","label":"CVSS score revised","source":"cvelistv5"}]}