{"cve":{"cve_id":"CVE-2021-32025","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00169,"epss_percentile":0.06475,"epss_as_of":"2026-06-23","description":"An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.","published_at":"2022-03-09T20:37:56Z","last_modified_at":null,"cvss_v3_score":8.1,"cvss_v3_vector":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-368"],"nvd_references":["http://support.blackberry.com/kb/articleDetail?articleNumber=000090868"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:15:38.410468Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"L","value_label":"Local"},{"metric":"AC","name":"Attack Complexity","value":"H","value_label":"High"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"C","value_label":"Changed"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"H","value_label":"High"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"blackberry","vendor_name":"BlackBerry","product_slug":"qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos","product_name":"QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)","version_start":"QNX SDP 6.4.0 to 7.0","version_start_inclusive":true,"version_end":"QNX SDP 6.4.0 to 7.0","version_end_inclusive":true,"cpe23_uri":"cve5:blackberry:qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos:QNX SDP 6.4.0 to 7.0:QNX SDP 6.4.0 to 7.0"},{"vendor_slug":"blackberry","vendor_name":"BlackBerry","product_slug":"qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos","product_name":"QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)","version_start":"QNX Momentics all 6.3.x versions","version_start_inclusive":true,"version_end":"QNX Momentics all 6.3.x versions","version_end_inclusive":true,"cpe23_uri":"cve5:blackberry:qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos:QNX Momentics all 6.3.x versions:QNX Momentics all 6.3.x versions"},{"vendor_slug":"blackberry","vendor_name":"BlackBerry","product_slug":"qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos","product_name":"QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)","version_start":"QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262","version_start_inclusive":true,"version_end":"QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262","version_end_inclusive":true,"cpe23_uri":"cve5:blackberry:qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos:QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262:QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262"},{"vendor_slug":"blackberry","vendor_name":"BlackBerry","product_slug":"qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos","product_name":"QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)","version_start":"QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262","version_start_inclusive":true,"version_end":"QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262","version_end_inclusive":true,"cpe23_uri":"cve5:blackberry:qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos:QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262:QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262"},{"vendor_slug":"blackberry","vendor_name":"BlackBerry","product_slug":"qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos","product_name":"QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)","version_start":"QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304","version_start_inclusive":true,"version_end":"QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304","version_end_inclusive":true,"cpe23_uri":"cve5:blackberry:qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos:QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304:QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304"},{"vendor_slug":"blackberry","vendor_name":"BlackBerry","product_slug":"qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos","product_name":"QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)","version_start":"QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304","version_start_inclusive":true,"version_end":"QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304","version_end_inclusive":true,"cpe23_uri":"cve5:blackberry:qnx-software-development-platform-sdp-qnx-os-for-medical-qosm-and-qnx-os-for-safety-qos:QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304:QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304"}],"exploit_refs":[],"news":[],"references":[{"url":"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2022-03-09T20:37:56Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:18:26.781604Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:18:26.781604Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:18:26.781604Z","label":"CVSS score revised","source":"cvelistv5"}]}