{"cve":{"cve_id":"CVE-2021-42554","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00327,"epss_percentile":0.25104,"epss_as_of":"2026-08-26","description":"An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.","published_at":"2022-02-03T01:40:56Z","last_modified_at":"2026-08-11T13:17:21.767000Z","cvss_v3_score":8.2,"cvss_v3_vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-787"],"nvd_references":["https://www.insyde.com/security-pledge","https://www.insyde.com/security-pledge/SA-2022012","https://security.netapp.com/advisory/ntap-20220216-0007/","https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"],"vuln_status":"Modified","trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-08-14T14:46:47.968730Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"L","value_label":"Local"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"H","value_label":"High"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"C","value_label":"Changed"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"H","value_label":"High"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"insyde","vendor_name":"insyde","product_slug":"insydeh2o","product_name":"insydeh2o","version_start":"5.0","version_start_inclusive":true,"version_end":"5.08.42","version_end_inclusive":false,"cpe23_uri":"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"ruggedcom-ape1808-firmware","product_name":"ruggedcom_ape1808_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-field-pg-m5-firmware","product_name":"simatic_field_pg_m5_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-field-pg-m6-firmware","product_name":"simatic_field_pg_m6_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc127e-firmware","product_name":"simatic_ipc127e_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc227g-firmware","product_name":"simatic_ipc227g_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc277g-firmware","product_name":"simatic_ipc277g_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc327g-firmware","product_name":"simatic_ipc327g_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc377g-firmware","product_name":"simatic_ipc377g_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc427e-firmware","product_name":"simatic_ipc427e_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc477e-firmware","product_name":"simatic_ipc477e_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc627e-firmware","product_name":"simatic_ipc627e_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc647e-firmware","product_name":"simatic_ipc647e_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc677e-firmware","product_name":"simatic_ipc677e_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-ipc847e-firmware","product_name":"simatic_ipc847e_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simatic-itp1000-firmware","product_name":"simatic_itp1000_firmware","version_start":null,"version_start_inclusive":null,"version_end":null,"version_end_inclusive":null,"cpe23_uri":"cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*"}],"exploit_refs":[],"news":[],"references":[{"url":"https://www.insyde.com/security-pledge","source_type":"MISC","tags":[]},{"url":"https://www.insyde.com/security-pledge/SA-2022012","source_type":"MISC","tags":[]},{"url":"https://security.netapp.com/advisory/ntap-20220216-0007/","source_type":"MISC","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2022-02-03T01:40:56Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-08-13T20:20:23.063882Z","label":"CVSS score revised","source":"nvd"},{"type":"cvss_changed","at":"2026-08-13T20:20:23.063882Z","label":"CVSS score revised","source":"nvd"},{"type":"cvss_changed","at":"2026-08-13T20:20:23.063882Z","label":"CVSS score revised","source":"nvd"}]}