{"cve":{"cve_id":"CVE-2022-39138","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00232,"epss_percentile":0.13766,"epss_as_of":"2026-06-23","description":"A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17284)","published_at":"2022-09-13T09:40:55Z","last_modified_at":null,"cvss_v3_score":null,"cvss_v3_vector":null,"cvss_v3_severity":null,"cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-787"],"nvd_references":["https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:18:09.341536Z"},"effective_severity":null,"badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":null,"metrics":[]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"parasolid-v33.1","product_name":"Parasolid V33.1","version_start":"All versions < V33.1.262","version_start_inclusive":true,"version_end":"All versions < V33.1.262","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:parasolid-v33.1:All versions < V33.1.262:All versions < V33.1.262"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"parasolid-v34.0","product_name":"Parasolid V34.0","version_start":"All versions < V34.0.252","version_start_inclusive":true,"version_end":"All versions < V34.0.252","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:parasolid-v34.0:All versions < V34.0.252:All versions < V34.0.252"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"parasolid-v34.1","product_name":"Parasolid V34.1","version_start":"All versions < V34.1.242","version_start_inclusive":true,"version_end":"All versions < V34.1.242","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:parasolid-v34.1:All versions < V34.1.242:All versions < V34.1.242"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"parasolid-v35.0","product_name":"Parasolid V35.0","version_start":"All versions <  V35.0.161","version_start_inclusive":true,"version_end":"All versions <  V35.0.161","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:parasolid-v35.0:All versions <  V35.0.161:All versions <  V35.0.161"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simcenter-femap-v2022.1","product_name":"Simcenter Femap V2022.1","version_start":"All versions < V2022.1.3","version_start_inclusive":true,"version_end":"All versions < V2022.1.3","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:simcenter-femap-v2022.1:All versions < V2022.1.3:All versions < V2022.1.3"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"simcenter-femap-v2022.2","product_name":"Simcenter Femap V2022.2","version_start":"All versions < V2022.2.2","version_start_inclusive":true,"version_end":"All versions < V2022.2.2","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:simcenter-femap-v2022.2:All versions < V2022.2.2:All versions < V2022.2.2"}],"exploit_refs":[],"news":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2022-09-13T09:40:55Z","label":"CVE published","source":null}]}