{"cve":{"cve_id":"CVE-2022-41629","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00589,"epss_percentile":0.43555,"epss_as_of":"2026-06-23","description":"\nDelta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.\n\n","published_at":"2022-10-31T19:51:27.025000Z","last_modified_at":null,"cvss_v3_score":7.5,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":true,"ssvc_technical_impact":"partial","cwes":["CWE-306"],"nvd_references":["https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T01:20:09.065395Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"N","value_label":"None"},{"metric":"A","name":"Availability","value":"N","value_label":"None"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"delta-electronics","vendor_name":"Delta Electronics","product_slug":"infrasuite-device-master","product_name":"InfraSuite Device Master","version_start":"0","version_start_inclusive":true,"version_end":"00.00.01a","version_end_inclusive":true,"cpe23_uri":"cve5:delta-electronics:infrasuite-device-master:0:00.00.01a"}],"exploit_refs":[],"news":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07","source_type":"VENDOR_ADVISORY","tags":["advisory"]}],"timeline":[{"type":"published","at":"2022-10-31T19:51:27.025000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:23:56.460136Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:23:56.460136Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:23:56.460136Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T01:20:09.065395Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:20:09.065395Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:20:09.065395Z","label":"SSVC decision revised","source":"vulnrichment"}]}