{"cve":{"cve_id":"CVE-2022-43514","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.01543,"epss_percentile":0.71727,"epss_as_of":"2026-06-23","description":"A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory.\r\nThis could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow Remote Code Execution.","published_at":"2023-01-10T11:39:39.909000Z","last_modified_at":null,"cvss_v3_score":7.7,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":false,"ssvc_technical_impact":"total","cwes":["CWE-22"],"nvd_references":["https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf","https://cert-portal.siemens.com/productcert/html/ssa-476715.html","https://cert-portal.siemens.com/productcert/html/ssa-556635.html"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T01:21:07.499748Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"H","value_label":"High"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"L","value_label":"Low"},{"metric":"E","name":"E","value":"P","value_label":"Physical"},{"metric":"RL","name":"RL","value":"O","value_label":"O"},{"metric":"RC","name":"RC","value":"C","value_label":"Changed"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"automation-license-manager-v5","product_name":"Automation License Manager V5","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:automation-license-manager-v5:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"automation-license-manager-v6","product_name":"Automation License Manager V6","version_start":"All versions < V6.0 SP9 Upd4","version_start_inclusive":true,"version_end":"All versions < V6.0 SP9 Upd4","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:automation-license-manager-v6:All versions < V6.0 SP9 Upd4:All versions < V6.0 SP9 Upd4"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"telecontrol-server-basic-v3","product_name":"TeleControl Server Basic V3","version_start":"0","version_start_inclusive":true,"version_end":"V3.1.2","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:telecontrol-server-basic-v3:0:V3.1.2"}],"exploit_refs":[],"news":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf","source_type":"MISC","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-476715.html","source_type":"MISC","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-556635.html","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2023-01-10T11:39:39.909000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:24:10.832026Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:24:10.832026Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:24:10.832026Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T01:21:07.499748Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:21:07.499748Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:21:07.499748Z","label":"SSVC decision revised","source":"vulnrichment"}]}