{"cve":{"cve_id":"CVE-2023-0432","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.01142,"epss_percentile":0.62526,"epss_as_of":"2026-06-23","description":"\nThe web configuration service of the affected device contains an authenticated command injection vulnerability. It can be used to execute system commands on the operating system (OS) from the device in the context of the user \"root.\" If the attacker has credentials for the web service, then the device could be fully compromised.\n\n\n\n","published_at":"2023-03-31T15:51:02.512000Z","last_modified_at":null,"cvss_v3_score":9.0,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","cvss_v3_severity":"CRITICAL","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":false,"ssvc_technical_impact":"total","cwes":["CWE-79"],"nvd_references":["https://www.cisa.gov/news-events/ics-advisories/icsa-23-033-05"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T01:23:47.661067Z"},"effective_severity":"CRITICAL","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"R","value_label":"Required"},{"metric":"S","name":"Scope","value":"C","value_label":"Changed"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"H","value_label":"High"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"delta-electronics","vendor_name":"Delta Electronics","product_slug":"dx-2100-l1-cn","product_name":"DX-2100-L1-CN","version_start":"1.5.0.10","version_start_inclusive":true,"version_end":"1.5.0.10","version_end_inclusive":true,"cpe23_uri":"cve5:delta-electronics:dx-2100-l1-cn:1.5.0.10:1.5.0.10"}],"exploit_refs":[],"news":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-033-05","source_type":"VENDOR_ADVISORY","tags":["advisory"]}],"timeline":[{"type":"published","at":"2023-03-31T15:51:02.512000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:25:38.989709Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:25:38.989709Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:25:38.989709Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T01:23:47.661067Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:23:47.661067Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:23:47.661067Z","label":"SSVC decision revised","source":"vulnrichment"}]}