{"cve":{"cve_id":"CVE-2023-24978","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00226,"epss_percentile":0.13029,"epss_as_of":"2026-06-23","description":"A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19788)","published_at":"2023-02-14T10:36:47.474000Z","last_modified_at":null,"cvss_v3_score":7.8,"cvss_v3_vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":false,"ssvc_technical_impact":"total","cwes":["CWE-824"],"nvd_references":["https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T01:27:25.549714Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"L","value_label":"Local"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"R","value_label":"Required"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"H","value_label":"High"},{"metric":"E","name":"E","value":"P","value_label":"Physical"},{"metric":"RL","name":"RL","value":"O","value_label":"O"},{"metric":"RC","name":"RC","value":"C","value_label":"Changed"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"tecnomatix-plant-simulation","product_name":"Tecnomatix Plant Simulation","version_start":"All versions < V2201.0006","version_start_inclusive":true,"version_end":"All versions < V2201.0006","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:tecnomatix-plant-simulation:All versions < V2201.0006:All versions < V2201.0006"}],"exploit_refs":[],"news":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2023-02-14T10:36:47.474000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:27:07.118971Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:27:07.118971Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:27:07.118971Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T01:27:25.549714Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:27:25.549714Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:27:25.549714Z","label":"SSVC decision revised","source":"vulnrichment"}]}