{"cve":{"cve_id":"CVE-2023-48430","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00585,"epss_percentile":0.4339,"epss_as_of":"2026-06-23","description":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.","published_at":"2023-12-12T11:27:22.091000Z","last_modified_at":null,"cvss_v3_score":2.7,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C","cvss_v3_severity":"LOW","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-392"],"nvd_references":["https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:20:59.612296Z"},"effective_severity":"LOW","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"H","value_label":"High"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"N","value_label":"None"},{"metric":"I","name":"Integrity","value":"N","value_label":"None"},{"metric":"A","name":"Availability","value":"L","value_label":"Low"},{"metric":"E","name":"E","value":"P","value_label":"Physical"},{"metric":"RL","name":"RL","value":"O","value_label":"O"},{"metric":"RC","name":"RC","value":"C","value_label":"Changed"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"sinec-ins","product_name":"SINEC INS","version_start":"All versions < V1.0 SP2 Update 2","version_start_inclusive":true,"version_end":"All versions < V1.0 SP2 Update 2","version_end_inclusive":true,"cpe23_uri":"cve5:siemens:sinec-ins:All versions < V1.0 SP2 Update 2:All versions < V1.0 SP2 Update 2"}],"exploit_refs":[],"news":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2023-12-12T11:27:22.091000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:30:36.171819Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:30:36.171819Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:30:36.171819Z","label":"CVSS score revised","source":"cvelistv5"}]}