{"cve":{"cve_id":"CVE-2024-10511","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00959,"epss_percentile":0.56867,"epss_as_of":"2026-06-23","description":"CWE-287: Improper Authentication vulnerability exists that could cause Denial of access to the web interface\nwhen someone on the local network repeatedly requests the /accessdenied URL.","published_at":"2024-12-11T09:04:50.225000Z","last_modified_at":null,"cvss_v3_score":5.3,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","cvss_v3_severity":"MEDIUM","cvss_v4_score":6.3,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","cvss_v4_severity":"MEDIUM","ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":true,"ssvc_technical_impact":"partial","cwes":["CWE-287"],"nvd_references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-345-01.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T01:47:04.007003Z"},"effective_severity":"MEDIUM","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"N","value_label":"None"},{"metric":"I","name":"Integrity","value":"N","value_label":"None"},{"metric":"A","name":"Availability","value":"L","value_label":"Low"}]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"P","value_label":"Present"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"N","value_label":"None"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"N","value_label":"None"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"N","value_label":"None"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"N","value_label":"None"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"}]},"affected":[{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"powerchute-serial-shutdown","product_name":"PowerChute™ Serial Shutdown","version_start":"Versions v1.2.0.301 and prior","version_start_inclusive":true,"version_end":"Versions v1.2.0.301 and prior","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:powerchute-serial-shutdown:Versions v1.2.0.301 and prior:Versions v1.2.0.301 and prior"}],"exploit_refs":[],"news":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-345-01.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2024-12-11T09:04:50.225000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:32:19.501865Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:19.501865Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:19.501865Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:19.501865Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:19.501865Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:19.501865Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T01:47:04.007003Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:47:04.007003Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:47:04.007003Z","label":"SSVC decision revised","source":"vulnrichment"}]}