{"cve":{"cve_id":"CVE-2024-11305","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.03725,"epss_percentile":0.88381,"epss_as_of":"2026-06-23","description":"A vulnerability classified as critical was found in Altenergy Power Control Software up to 20241108. This vulnerability affects the function get_status_zigbee of the file /index.php/display/status_zigbee. The manipulation of the argument date leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","published_at":"2024-11-18T00:31:04.617000Z","last_modified_at":null,"cvss_v3_score":6.3,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","cvss_v3_severity":"MEDIUM","cvss_v4_score":5.3,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","cvss_v4_severity":"MEDIUM","ssvc_decision":null,"ssvc_exploitation":"poc","ssvc_automatable":false,"ssvc_technical_impact":"partial","cwes":["CWE-89","CWE-74"],"nvd_references":["https://vuldb.com/?id.284914","https://vuldb.com/?ctiid.284914","https://vuldb.com/?submit.439800","https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/HYO%3BY)v%3B4%5C)jLCjp/Altenergy%20has%20a%20SQL%20injection%20vulnerability_status_zigbee.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T01:49:24.977771Z"},"effective_severity":"MEDIUM","badges":["poc"],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"L","value_label":"Low"},{"metric":"I","name":"Integrity","value":"L","value_label":"Low"},{"metric":"A","name":"Availability","value":"L","value_label":"Low"}]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"N","value_label":"None"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"N","value_label":"None"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"}]},"affected":[{"vendor_slug":"altenergy","vendor_name":"Altenergy","product_slug":"power-control-software","product_name":"Power Control Software","version_start":"20241108","version_start_inclusive":true,"version_end":"20241108","version_end_inclusive":true,"cpe23_uri":"cve5:altenergy:power-control-software:20241108:20241108"}],"exploit_refs":[{"source":"nuclei","kind":"nuclei","url":"https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2024/CVE-2024-11305.yaml","title":"Altenergy Power Control Software - SQL Injection","author":"s4e-io","disclosed_at":null}],"news":[],"references":[{"url":"https://vuldb.com/?id.284914","source_type":"MISC","tags":[]},{"url":"https://vuldb.com/?ctiid.284914","source_type":"MISC","tags":[]},{"url":"https://vuldb.com/?submit.439800","source_type":"MISC","tags":[]},{"url":"https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/HYO%3BY)v%3B4%5C)jLCjp/Altenergy%20has%20a%20SQL%20injection%20vulnerability_status_zigbee.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2024-11-18T00:31:04.617000Z","label":"CVE published","source":null},{"type":"poc_available","at":"2026-06-24T00:29:48.638073Z","label":"Public PoC available","source":"nuclei"},{"type":"cvss_changed","at":"2026-06-28T17:32:29.086311Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:29.086311Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:29.086311Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:29.086311Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:29.086311Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:32:29.086311Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T01:49:24.977771Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:49:24.977771Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:49:24.977771Z","label":"SSVC decision revised","source":"vulnrichment"}]}