{"cve":{"cve_id":"CVE-2024-30190","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00196,"epss_percentile":0.09419,"epss_as_of":"2026-06-23","description":"A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 2 \"Abuse the queue for network disruptions\" of CVE-2022-47522.\r\n\r\nAffected devices can be tricked into enabling its power-saving mechanisms for a victim client. This could allow a physically proximate attacker to execute disconnection and denial-of-service attacks.","published_at":"2024-04-09T08:34:41.545000Z","last_modified_at":null,"cvss_v3_score":6.1,"cvss_v3_vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H","cvss_v3_severity":"MEDIUM","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":false,"ssvc_technical_impact":"partial","cwes":["CWE-290"],"nvd_references":["https://cert-portal.siemens.com/productcert/html/ssa-457702.html"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T01:57:18.952838Z"},"effective_severity":"MEDIUM","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"A","value_label":"Adjacent"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"R","value_label":"Required"},{"metric":"S","name":"Scope","value":"C","value_label":"Changed"},{"metric":"C","name":"Confidentiality","value":"N","value_label":"None"},{"metric":"I","name":"Integrity","value":"N","value_label":"None"},{"metric":"A","name":"Availability","value":"H","value_label":"High"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w1748-1-m12","product_name":"SCALANCE W1748-1 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w1748-1-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w1788-1-m12","product_name":"SCALANCE W1788-1 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w1788-1-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w1788-2-eec-m12","product_name":"SCALANCE W1788-2 EEC M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w1788-2-eec-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w1788-2ia-m12","product_name":"SCALANCE W1788-2IA M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w1788-2ia-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w1788-2-m12","product_name":"SCALANCE W1788-2 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w1788-2-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w721-1-rj45","product_name":"SCALANCE W721-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w721-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w722-1-rj45","product_name":"SCALANCE W722-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w722-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w734-1-rj45","product_name":"SCALANCE W734-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w734-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w734-1-rj45-usa","product_name":"SCALANCE W734-1 RJ45 (USA)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w734-1-rj45-usa:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w738-1-m12","product_name":"SCALANCE W738-1 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w738-1-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w748-1-m12","product_name":"SCALANCE W748-1 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w748-1-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w748-1-rj45","product_name":"SCALANCE W748-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w748-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w761-1-rj45","product_name":"SCALANCE W761-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w761-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w774-1-m12-eec","product_name":"SCALANCE W774-1 M12 EEC","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w774-1-m12-eec:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w774-1-rj45","product_name":"SCALANCE W774-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w774-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w774-1-rj45-usa","product_name":"SCALANCE W774-1 RJ45 (USA)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w774-1-rj45-usa:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w778-1-m12","product_name":"SCALANCE W778-1 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w778-1-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w778-1-m12-eec","product_name":"SCALANCE W778-1 M12 EEC","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w778-1-m12-eec:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w778-1-m12-eec-usa","product_name":"SCALANCE W778-1 M12 EEC (USA)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w778-1-m12-eec-usa:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w786-1-rj45","product_name":"SCALANCE W786-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w786-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w786-2ia-rj45","product_name":"SCALANCE W786-2IA RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w786-2ia-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w786-2-rj45","product_name":"SCALANCE W786-2 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w786-2-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w786-2-sfp","product_name":"SCALANCE W786-2 SFP","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w786-2-sfp:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w788-1-m12","product_name":"SCALANCE W788-1 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w788-1-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w788-1-rj45","product_name":"SCALANCE W788-1 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w788-1-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w788-2-m12","product_name":"SCALANCE W788-2 M12","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w788-2-m12:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w788-2-m12-eec","product_name":"SCALANCE W788-2 M12 EEC","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w788-2-m12-eec:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-w788-2-rj45","product_name":"SCALANCE W788-2 RJ45","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-w788-2-rj45:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wam763-1","product_name":"SCALANCE WAM763-1","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wam763-1:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wam766-1-eec-eu","product_name":"SCALANCE WAM766-1 EEC (EU)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wam766-1-eec-eu:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wam766-1-eec-us","product_name":"SCALANCE WAM766-1 EEC (US)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wam766-1-eec-us:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wam766-1-eu","product_name":"SCALANCE WAM766-1 (EU)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wam766-1-eu:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wam766-1-us","product_name":"SCALANCE WAM766-1 (US)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wam766-1-us:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wum763-1","product_name":"SCALANCE WUM763-1","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wum763-1:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wum766-1-eu","product_name":"SCALANCE WUM766-1 (EU)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wum766-1-eu:0:*"},{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"scalance-wum766-1-us","product_name":"SCALANCE WUM766-1 (US)","version_start":"0","version_start_inclusive":true,"version_end":"*","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:scalance-wum766-1-us:0:*"}],"exploit_refs":[],"news":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-457702.html","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2024-04-09T08:34:41.545000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:35:22.123889Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:35:22.123889Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:35:22.123889Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T01:57:18.952838Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:57:18.952838Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T01:57:18.952838Z","label":"SSVC decision revised","source":"vulnrichment"}]}