{"cve":{"cve_id":"CVE-2024-4065","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.01643,"epss_percentile":0.7335,"epss_as_of":"2026-06-23","description":"A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","published_at":"2024-04-23T20:00:07.093000Z","last_modified_at":null,"cvss_v3_score":8.8,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":false,"ssvc_technical_impact":"total","cwes":["CWE-121"],"nvd_references":["https://vuldb.com/?id.261791","https://vuldb.com/?ctiid.261791","https://vuldb.com/?submit.316494","https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T02:12:16.527185Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"H","value_label":"High"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"tenda","vendor_name":"tenda","product_slug":"ac8","product_name":"AC8","version_start":"16.03.34.09","version_start_inclusive":true,"version_end":"16.03.34.09","version_end_inclusive":true,"cpe23_uri":"cve5:tenda:ac8:16.03.34.09:16.03.34.09"}],"exploit_refs":[],"news":[],"references":[{"url":"https://vuldb.com/?id.261791","source_type":"MISC","tags":[]},{"url":"https://vuldb.com/?ctiid.261791","source_type":"MISC","tags":[]},{"url":"https://vuldb.com/?submit.316494","source_type":"MISC","tags":[]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2024-04-23T20:00:07.093000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:38:23.080966Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:38:23.080966Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:38:23.080966Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T02:12:16.527185Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T02:12:16.527185Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T02:12:16.527185Z","label":"SSVC decision revised","source":"vulnrichment"}]}