{"cve":{"cve_id":"CVE-2024-46890","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00715,"epss_percentile":0.48883,"epss_as_of":"2026-06-23","description":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS.","published_at":"2024-11-12T12:49:41.829000Z","last_modified_at":null,"cvss_v3_score":9.1,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","cvss_v3_severity":"CRITICAL","cvss_v4_score":9.4,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","cvss_v4_severity":"CRITICAL","ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":false,"ssvc_technical_impact":"partial","cwes":["CWE-78"],"nvd_references":["https://cert-portal.siemens.com/productcert/html/ssa-915275.html"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T02:09:06.230884Z"},"effective_severity":"CRITICAL","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"H","value_label":"High"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"C","value_label":"Changed"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"H","value_label":"High"},{"metric":"E","name":"E","value":"P","value_label":"Physical"},{"metric":"RL","name":"RL","value":"O","value_label":"O"},{"metric":"RC","name":"RC","value":"C","value_label":"Changed"}]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"H","value_label":"High"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"H","value_label":"High"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"H","value_label":"High"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"H","value_label":"High"},{"metric":"SA","name":"Availability (Subsequent System)","value":"H","value_label":"High"}]},"affected":[{"vendor_slug":"siemens","vendor_name":"Siemens","product_slug":"sinec-ins","product_name":"SINEC INS","version_start":"0","version_start_inclusive":true,"version_end":"V1.0 SP2 Update 3","version_end_inclusive":false,"cpe23_uri":"cve5:siemens:sinec-ins:0:V1.0 SP2 Update 3"}],"exploit_refs":[],"news":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-915275.html","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2024-11-12T12:49:41.829000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:37:59.364629Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:37:59.364629Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:37:59.364629Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:37:59.364629Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:37:59.364629Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:37:59.364629Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T02:09:06.230884Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T02:09:06.230884Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T02:09:06.230884Z","label":"SSVC decision revised","source":"vulnrichment"}]}