{"cve":{"cve_id":"CVE-2024-5176","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00477,"epss_percentile":0.3746,"epss_as_of":"2026-06-23","description":"Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior.","published_at":"2024-05-31T17:26:05.140000Z","last_modified_at":null,"cvss_v3_score":null,"cvss_v3_vector":null,"cvss_v3_severity":null,"cvss_v4_score":9.4,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L","cvss_v4_severity":"CRITICAL","ssvc_decision":null,"ssvc_exploitation":"none","ssvc_automatable":false,"ssvc_technical_impact":"total","cwes":["CWE-522"],"nvd_references":["https://cisa.gov/news-events/ics-medical-advisories/icsma-24-151-01"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-29T02:19:11.094487Z"},"effective_severity":"CRITICAL","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":null,"metrics":[]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"P","value_label":"Passive"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"H","value_label":"High"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"H","value_label":"High"},{"metric":"SA","name":"Availability (Subsequent System)","value":"L","value_label":"Low"}]},"affected":[{"vendor_slug":"baxter","vendor_name":"Baxter","product_slug":"welch-allyn-configuration-tool","product_name":"Welch Allyn Configuration Tool","version_start":"0","version_start_inclusive":true,"version_end":"1.9.4.1","version_end_inclusive":true,"cpe23_uri":"cve5:baxter:welch-allyn-configuration-tool:0:1.9.4.1"}],"exploit_refs":[],"news":[],"references":[{"url":"https://cisa.gov/news-events/ics-medical-advisories/icsma-24-151-01","source_type":"VENDOR_ADVISORY","tags":["advisory"]}],"timeline":[{"type":"published","at":"2024-05-31T17:26:05.140000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:39:43.518446Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:39:43.518446Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:39:43.518446Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"ssvc_changed","at":"2026-06-29T02:19:11.094487Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T02:19:11.094487Z","label":"SSVC decision revised","source":"vulnrichment"},{"type":"ssvc_changed","at":"2026-06-29T02:19:11.094487Z","label":"SSVC decision revised","source":"vulnrichment"}]}