{"cve":{"cve_id":"CVE-2025-3117","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00187,"epss_percentile":0.08349,"epss_as_of":"2026-06-23","description":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability\nexists impacting configuration file paths that could cause an unvalidated data injected by authenticated\nmalicious user leading to modify or read data in a victim’s browser.","published_at":"2025-06-10T08:43:15.540000Z","last_modified_at":null,"cvss_v3_score":5.4,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","cvss_v3_severity":"MEDIUM","cvss_v4_score":5.1,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N","cvss_v4_severity":"MEDIUM","ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-79"],"nvd_references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-161-02.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:26:21.046441Z"},"effective_severity":"MEDIUM","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"R","value_label":"Required"},{"metric":"S","name":"Scope","value":"C","value_label":"Changed"},{"metric":"C","name":"Confidentiality","value":"L","value_label":"Low"},{"metric":"I","name":"Integrity","value":"L","value_label":"Low"},{"metric":"A","name":"Availability","value":"N","value_label":"None"}]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"P","value_label":"Passive"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"N","value_label":"None"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"N","value_label":"None"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"L","value_label":"Low"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"L","value_label":"Low"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"}]},"affected":[{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"modicon-controllers-m241-m251","product_name":"Modicon Controllers M241/M251","version_start":"Versions prior to 5.3.12.51","version_start_inclusive":true,"version_end":"Versions prior to 5.3.12.51","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:modicon-controllers-m241-m251:Versions prior to 5.3.12.51:Versions prior to 5.3.12.51"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"modicon-controllers-m262","product_name":"Modicon Controllers M262","version_start":"Versions prior to 5.3.9.18","version_start_inclusive":true,"version_end":"Versions prior to 5.3.9.18","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:modicon-controllers-m262:Versions prior to 5.3.9.18:Versions prior to 5.3.9.18"}],"exploit_refs":[],"news":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-161-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-161-02.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2025-06-10T08:43:15.540000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:45:52.194190Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:45:52.194190Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:45:52.194190Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:45:52.194190Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:45:52.194190Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:45:52.194190Z","label":"CVSS score revised","source":"cvelistv5"}]}