{"cve":{"cve_id":"CVE-2025-37182","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00404,"epss_percentile":0.32075,"epss_as_of":"2026-06-23","description":"Vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to perform SQL injection attacks. Successful  exploitation could allow an attacker to execute arbitrary SQL commands on the underlying database, potentially leading to unauthorized data access or data manipulation.","published_at":"2026-01-14T16:17:12.170000Z","last_modified_at":null,"cvss_v3_score":7.2,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-89"],"nvd_references":["https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04992en_us&docLocale=en_US"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:26:35.811048Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"H","value_label":"High"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"H","value_label":"High"},{"metric":"A","name":"Availability","value":"H","value_label":"High"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"hewlett-packard-enterprise-hpe","vendor_name":"Hewlett Packard Enterprise (HPE)","product_slug":"edgeconnect-sd-wan-orchestrator","product_name":"EdgeConnect SD-WAN Orchestrator","version_start":"9.5.0","version_start_inclusive":true,"version_end":"9.6.0","version_end_inclusive":true,"cpe23_uri":"cve5:hewlett-packard-enterprise-hpe:edgeconnect-sd-wan-orchestrator:9.5.0:9.6.0"},{"vendor_slug":"hewlett-packard-enterprise-hpe","vendor_name":"Hewlett Packard Enterprise (HPE)","product_slug":"edgeconnect-sd-wan-orchestrator","product_name":"EdgeConnect SD-WAN Orchestrator","version_start":"9.4.0","version_start_inclusive":true,"version_end":"9.4.4","version_end_inclusive":true,"cpe23_uri":"cve5:hewlett-packard-enterprise-hpe:edgeconnect-sd-wan-orchestrator:9.4.0:9.4.4"}],"exploit_refs":[],"news":[],"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04992en_us&docLocale=en_US","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2026-01-14T16:17:12.170000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:45:17.091772Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:45:17.091772Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:45:17.091772Z","label":"CVSS score revised","source":"cvelistv5"}]}