{"cve":{"cve_id":"CVE-2025-54925","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00421,"epss_percentile":0.33534,"epss_as_of":"2026-06-23","description":"CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.","published_at":"2025-08-20T13:44:21.662000Z","last_modified_at":null,"cvss_v3_score":7.5,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","cvss_v3_severity":"HIGH","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-918"],"nvd_references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-224-02.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:27:36.992993Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"N","value_label":"None"},{"metric":"A","name":"Availability","value":"N","value_label":"None"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"ecostruxure-power-monitoring-expert-pme","product_name":"EcoStruxure™ Power Monitoring Expert (PME)","version_start":"Version 2022","version_start_inclusive":true,"version_end":"Version 2022","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:ecostruxure-power-monitoring-expert-pme:Version 2022:Version 2022"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"ecostruxure-power-monitoring-expert-pme","product_name":"EcoStruxure™ Power Monitoring Expert (PME)","version_start":"Version 2023","version_start_inclusive":true,"version_end":"Version 2023","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:ecostruxure-power-monitoring-expert-pme:Version 2023:Version 2023"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"ecostruxure-power-monitoring-expert-pme","product_name":"EcoStruxure™ Power Monitoring Expert (PME)","version_start":"Version 2024","version_start_inclusive":true,"version_end":"Version 2024","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:ecostruxure-power-monitoring-expert-pme:Version 2024:Version 2024"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"ecostruxure-power-monitoring-expert-pme","product_name":"EcoStruxure™ Power Monitoring Expert (PME)","version_start":"Version 2024 R2","version_start_inclusive":true,"version_end":"Version 2024 R2","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:ecostruxure-power-monitoring-expert-pme:Version 2024 R2:Version 2024 R2"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"ecostruxure-power-operation-epo-advanced-reporting-and-dashboards-module","product_name":"EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module","version_start":"Version 2022 w/ Advanced Reporting Module","version_start_inclusive":true,"version_end":"Version 2022 w/ Advanced Reporting Module","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:ecostruxure-power-operation-epo-advanced-reporting-and-dashboards-module:Version 2022 w/ Advanced Reporting Module:Version 2022 w/ Advanced Reporting Module"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"ecostruxure-power-operation-epo-advanced-reporting-and-dashboards-module","product_name":"EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module","version_start":"Version 2024 w/ Advanced Reporting Module","version_start_inclusive":true,"version_end":"Version 2024 w/ Advanced Reporting Module","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:ecostruxure-power-operation-epo-advanced-reporting-and-dashboards-module:Version 2024 w/ Advanced Reporting Module:Version 2024 w/ Advanced Reporting Module"}],"exploit_refs":[],"news":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-224-02.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2025-08-20T13:44:21.662000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:47:54.064885Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:47:54.064885Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:47:54.064885Z","label":"CVSS score revised","source":"cvelistv5"}]}