{"cve":{"cve_id":"CVE-2025-5824","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00146,"epss_percentile":0.04169,"epss_as_of":"2026-06-23","description":"Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353.","published_at":"2025-06-25T17:59:54.446000Z","last_modified_at":null,"cvss_v3_score":5.0,"cvss_v3_vector":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L","cvss_v3_severity":"MEDIUM","cvss_v4_score":null,"cvss_v4_vector":null,"cvss_v4_severity":null,"ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-346"],"nvd_references":["https://www.zerodayinitiative.com/advisories/ZDI-25-343/"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:27:45.998527Z"},"effective_severity":"MEDIUM","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"A","value_label":"Adjacent"},{"metric":"AC","name":"Attack Complexity","value":"H","value_label":"High"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"L","value_label":"Low"},{"metric":"I","name":"Integrity","value":"L","value_label":"Low"},{"metric":"A","name":"Availability","value":"L","value_label":"Low"}]},"cvss_v4_decoded":{"version":null,"metrics":[]},"affected":[{"vendor_slug":"autel","vendor_name":"Autel","product_slug":"autel-maxicharger-ac-wallbox-commercial","product_name":"Autel MaxiCharger AC Wallbox Commercial","version_start":"1.36.00","version_start_inclusive":true,"version_end":"1.36.00","version_end_inclusive":true,"cpe23_uri":"cve5:autel:autel-maxicharger-ac-wallbox-commercial:1.36.00:1.36.00"}],"exploit_refs":[],"news":[],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-25-343/","source_type":"VENDOR_ADVISORY","tags":["advisory"]}],"timeline":[{"type":"published","at":"2025-06-25T17:59:54.446000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:48:34.338798Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:48:34.338798Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:48:34.338798Z","label":"CVSS score revised","source":"cvelistv5"}]}