{"cve":{"cve_id":"CVE-2025-6376","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00205,"epss_percentile":0.10429,"epss_as_of":"2026-06-23","description":"A remote\ncode execution security issue exists in the Rockwell Automation Arena®.  A crafted DOE\nfile can force Arena Simulation to write beyond the boundaries of an allocated\nobject. Exploitation\nrequires user interaction, such as opening a malicious file within the software.\nIf exploited, a threat actor could execute arbitrary code on the target system.\nThe software must run under the context of the administrator in order to cause\nworse case impact. This is reflected in the Rockwell CVSS score, as AT:P.","published_at":"2025-07-09T20:13:45.320000Z","last_modified_at":null,"cvss_v3_score":null,"cvss_v3_vector":null,"cvss_v3_severity":null,"cvss_v4_score":7.1,"cvss_v4_vector":"CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","cvss_v4_severity":"HIGH","ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-20"],"nvd_references":["https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1729.html"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:28:06.112693Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":null,"metrics":[]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"L","value_label":"Local"},{"metric":"AC","name":"Attack Complexity","value":"H","value_label":"High"},{"metric":"AT","name":"Attack Requirements","value":"P","value_label":"Present"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"A","value_label":"Active"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"H","value_label":"High"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"N","value_label":"None"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"N","value_label":"None"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"}]},"affected":[{"vendor_slug":"rockwell-automation","vendor_name":"Rockwell Automation","product_slug":"arena","product_name":"Arena®","version_start":"<=16.20.08","version_start_inclusive":true,"version_end":"<=16.20.08","version_end_inclusive":true,"cpe23_uri":"cve5:rockwell-automation:arena:<=16.20.08:<=16.20.08"}],"exploit_refs":[],"news":[],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1729.html","source_type":"VENDOR_ADVISORY","tags":["advisory"]}],"timeline":[{"type":"published","at":"2025-07-09T20:13:45.320000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:49:31.027096Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:49:31.027096Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:49:31.027096Z","label":"CVSS score revised","source":"cvelistv5"}]}