{"cve":{"cve_id":"CVE-2025-7330","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00188,"epss_percentile":0.08513,"epss_as_of":"2026-06-23","description":"A cross-site request forgery security issue exists in the product and version listed. The vulnerability stems from missing CSRF checks on the impacted form. This allows for unintended configuration modification if an attacker can convince a logged in admin to visit a crafted link.","published_at":"2025-10-14T12:43:40.198000Z","last_modified_at":null,"cvss_v3_score":null,"cvss_v3_vector":null,"cvss_v3_severity":null,"cvss_v4_score":7.0,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N","cvss_v4_severity":"HIGH","ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-352"],"nvd_references":["https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1756.html"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:28:31.109265Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":null,"metrics":[]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"A","value_label":"Active"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"N","value_label":"None"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"H","value_label":"High"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"N","value_label":"None"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"N","value_label":"None"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"}]},"affected":[{"vendor_slug":"rockwell-automation","vendor_name":"Rockwell Automation","product_slug":"comms-1783-natr","product_name":"Comms - 1783-NATR","version_start":"Version 1.006 and prior","version_start_inclusive":true,"version_end":"Version 1.006 and prior","version_end_inclusive":true,"cpe23_uri":"cve5:rockwell-automation:comms-1783-natr:Version 1.006 and prior:Version 1.006 and prior"}],"exploit_refs":[],"news":[],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1756.html","source_type":"VENDOR_ADVISORY","tags":["advisory"]}],"timeline":[{"type":"published","at":"2025-10-14T12:43:40.198000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:49:45.838521Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:49:45.838521Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:49:45.838521Z","label":"CVSS score revised","source":"cvelistv5"}]}