{"cve":{"cve_id":"CVE-2026-7694","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00325,"epss_percentile":0.2408,"epss_as_of":"2026-06-23","description":"A flaw has been found in Acrel Electrical ECEMS Enterprise Microgrid Energy Efficiency Management System 1.3.0. The impacted element is an unknown function of the file /SubstationWEBV2/main/elecMaxMinAvgValue. Executing a manipulation of the argument fCircuitids can lead to sql injection. The attack can be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","published_at":"2026-05-03T11:45:39.522000Z","last_modified_at":null,"cvss_v3_score":7.3,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","cvss_v3_severity":"HIGH","cvss_v4_score":6.9,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","cvss_v4_severity":"MEDIUM","ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-89","CWE-74"],"nvd_references":["https://vuldb.com/vuln/360863","https://vuldb.com/vuln/360863/cti","https://vuldb.com/submit/803271","https://ucn9h68n9289.feishu.cn/wiki/WZMewApmsiT3PMkCJfzcASEznOb"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-06-28T23:31:06.397803Z"},"effective_severity":"MEDIUM","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"L","value_label":"Low"},{"metric":"I","name":"Integrity","value":"L","value_label":"Low"},{"metric":"A","name":"Availability","value":"L","value_label":"Low"},{"metric":"E","name":"E","value":"P","value_label":"Physical"},{"metric":"RL","name":"RL","value":"X","value_label":"X"},{"metric":"RC","name":"RC","value":"R","value_label":"Required"}]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"N","value_label":"None"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"L","value_label":"Low"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"N","value_label":"None"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"N","value_label":"None"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"},{"metric":"E","name":"E","value":"P","value_label":"Physical"}]},"affected":[{"vendor_slug":"acrel-electrical","vendor_name":"acrel_electrical","product_slug":"ecems-enterprise-microgrid-energy-efficiency-management-system","product_name":"ECEMS Enterprise Microgrid Energy Efficiency Management System","version_start":"1.3.0","version_start_inclusive":true,"version_end":"1.3.0","version_end_inclusive":true,"cpe23_uri":"cve5:acrel-electrical:ecems-enterprise-microgrid-energy-efficiency-management-system:1.3.0:1.3.0"}],"exploit_refs":[],"news":[],"references":[{"url":"https://vuldb.com/vuln/360863","source_type":"MISC","tags":[]},{"url":"https://vuldb.com/vuln/360863/cti","source_type":"MISC","tags":[]},{"url":"https://vuldb.com/submit/803271","source_type":"MISC","tags":[]},{"url":"https://ucn9h68n9289.feishu.cn/wiki/WZMewApmsiT3PMkCJfzcASEznOb","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2026-05-03T11:45:39.522000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:56:12.360668Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:56:12.360668Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:56:12.360668Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:56:12.360668Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:56:12.360668Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:56:12.360668Z","label":"CVSS score revised","source":"cvelistv5"}]}