{"cve":{"cve_id":"CVE-2026-8045","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":0.00387,"epss_percentile":0.31162,"epss_as_of":"2026-10-15","description":"CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.","published_at":"2026-06-09T14:41:56.266000Z","last_modified_at":"2026-07-20T20:10:00.110000Z","cvss_v3_score":6.5,"cvss_v3_vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","cvss_v3_severity":"MEDIUM","cvss_v4_score":7.1,"cvss_v4_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","cvss_v4_severity":"HIGH","ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-611"],"nvd_references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-01.pdf"],"vuln_status":"Analyzed","trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-24T00:09:39.878444Z","updated_at":"2026-07-21T06:39:40.188048Z"},"effective_severity":"HIGH","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":"3.1","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"S","name":"Scope","value":"U","value_label":"Unchanged"},{"metric":"C","name":"Confidentiality","value":"H","value_label":"High"},{"metric":"I","name":"Integrity","value":"N","value_label":"None"},{"metric":"A","name":"Availability","value":"N","value_label":"None"}]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"N","value_label":"Network"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"L","value_label":"Low"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"N","value_label":"None"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"N","value_label":"None"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"N","value_label":"None"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"N","value_label":"None"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"}]},"affected":[{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"ecostruxure-it-data-center-expert","product_name":"EcoStruxure™ IT Data Center Expert","version_start":"v9.1.1 and Prior","version_start_inclusive":true,"version_end":"v9.1.1 and Prior","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:ecostruxure-it-data-center-expert:v9.1.1 and Prior:v9.1.1 and Prior"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"struxureware-data-center-expert","product_name":"StruxureWare Data Center Expert","version_start":null,"version_start_inclusive":null,"version_end":"9.1.2","version_end_inclusive":false,"cpe23_uri":"cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*"}],"exploit_refs":[],"news":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-01.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2026-06-09T14:41:56.266000Z","label":"CVE published","source":null},{"type":"cvss_changed","at":"2026-06-28T17:56:17.788615Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:56:17.788615Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-06-28T17:56:17.788615Z","label":"CVSS score revised","source":"cvelistv5"},{"type":"cvss_changed","at":"2026-07-21T06:39:40.188048Z","label":"CVSS score revised","source":"nvd"},{"type":"cvss_changed","at":"2026-07-21T06:39:40.188048Z","label":"CVSS score revised","source":"nvd"},{"type":"cvss_changed","at":"2026-07-21T06:39:40.188048Z","label":"CVSS score revised","source":"nvd"}]}