{"cve":{"cve_id":"CVE-2026-9651","is_kev":false,"kev_date_added":null,"kev_vendor_project":null,"kev_product":null,"kev_vulnerability_name":null,"kev_short_description":null,"kev_required_action":null,"kev_due_date":null,"kev_known_ransomware":null,"kev_notes":null,"kev_cwes":null,"epss_score":null,"epss_percentile":null,"epss_as_of":null,"description":"CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.","published_at":"2026-06-25T14:47:24.496000Z","last_modified_at":null,"cvss_v3_score":null,"cvss_v3_vector":null,"cvss_v3_severity":null,"cvss_v4_score":6.7,"cvss_v4_vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","cvss_v4_severity":"MEDIUM","ssvc_decision":null,"ssvc_exploitation":null,"ssvc_automatable":null,"ssvc_technical_impact":null,"cwes":["CWE-732"],"nvd_references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf"],"vuln_status":null,"trending_score":null,"is_trending":false,"has_trended":false,"trended_number_one":false,"trending_peak_score":null,"trending_peak_rank":null,"started_trending_at":null,"trended_number_one_at":null,"summary_generated":null,"summary_generated_at":null,"summary_model":null,"created_at":"2026-06-28T17:56:27.543306Z","updated_at":"2026-06-28T23:31:13.439411Z"},"effective_severity":"MEDIUM","badges":[],"impact_analysis":[],"cvss_v3_decoded":{"version":null,"metrics":[]},"cvss_v4_decoded":{"version":"4.0","metrics":[{"metric":"AV","name":"Attack Vector","value":"L","value_label":"Local"},{"metric":"AC","name":"Attack Complexity","value":"L","value_label":"Low"},{"metric":"AT","name":"Attack Requirements","value":"N","value_label":"None"},{"metric":"PR","name":"Privileges Required","value":"H","value_label":"High"},{"metric":"UI","name":"User Interaction","value":"N","value_label":"None"},{"metric":"VC","name":"Confidentiality (Vulnerable System)","value":"H","value_label":"High"},{"metric":"VI","name":"Integrity (Vulnerable System)","value":"N","value_label":"None"},{"metric":"VA","name":"Availability (Vulnerable System)","value":"N","value_label":"None"},{"metric":"SC","name":"Confidentiality (Subsequent System)","value":"N","value_label":"None"},{"metric":"SI","name":"Integrity (Subsequent System)","value":"N","value_label":"None"},{"metric":"SA","name":"Availability (Subsequent System)","value":"N","value_label":"None"}]},"affected":[{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"easylogic-t150-formerly-saitel-dr-remote-terminal-unit-controller","product_name":"EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller","version_start":"Version 11.06.31 and prior","version_start_inclusive":true,"version_end":"Version 11.06.31 and prior","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:easylogic-t150-formerly-saitel-dr-remote-terminal-unit-controller:Version 11.06.31 and prior:Version 11.06.31 and prior"},{"vendor_slug":"schneider-electric","vendor_name":"Schneider Electric","product_slug":"saitel-dp-remote-terminal-unit-controller","product_name":"Saitel DP Remote Terminal Unit & Controller","version_start":"Version 11.06.37 and prior","version_start_inclusive":true,"version_end":"Version 11.06.37 and prior","version_end_inclusive":true,"cpe23_uri":"cve5:schneider-electric:saitel-dp-remote-terminal-unit-controller:Version 11.06.37 and prior:Version 11.06.37 and prior"}],"exploit_refs":[],"news":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf","source_type":"MISC","tags":[]}],"timeline":[{"type":"published","at":"2026-06-25T14:47:24.496000Z","label":"CVE published","source":null}]}